At present, the use of refrigeration equipment in hospital is very common. We need to master the correct use knowledge and do a good job of maintenance in time so as to keep these refrigeration equipment in normal operation, give full play to its maximum effect, and create a more comfortable and comfortable medical and working environment for patients and staff, so as to better serve patients and create greater social benefits for the hospital And economic benefits.
Hospital refrigeration equipment must be in a normal and good state to ensure its normal operation and achieve the above-mentioned role. In order to ensure the normal operation of hospital refrigeration equipment, we must do the following work:
3.1 regularly remove dust for air conditioning, refrigerator and other refrigeration equipment. The main problem is the dust removal of air conditioning. Due to the long working time of the air conditioner in the hospital, the air flow is much larger, and it is easier to have dust attached to the air conditioner, such as pipes, filters, fans and other places. If the dust is attached to the pipe, it will affect the heat absorption and heat dissipation function of the pipe; if there is too much dust attached to the filter screen, it will affect the air flow; if there is too much dust on the fan, it may cause the fan to rotate unsmoothly.
3.2 check the electrical components of air conditioner and refrigerator, such as compressor and temperature controller, and replace them in time in case of any damage. In particular, the damage of some small electrical components, such as temperature controller, should be found and replaced in time, otherwise the compressor will not run or run continuously due to these small faults, which will damage the compressor.
3.3 always check whether there is leakage of medium substance, i.e. refrigerant. If the refrigerant leaks, and to a certain extent, it may also cause poor refrigeration effect or no refrigeration at all.
3.4 many parts of the hospital air conditioner are hung on the outdoor wall, especially the single air conditioner. We should often pay attention to whether the bracket of the hanging air conditioner is in good condition, so as to avoid the damage of bracket caused by corrosion and other factors, which will cause the air conditioner to fall off and other situations, leading to some unnecessary accidental loss or injury.
3.5 the maintenance of hospital refrigeration equipment has its particularity: its surface, pipeline, gap, filter screen and other places often have a large number of bacteria and virus microorganisms, so it needs to be disinfected regularly, which can be used to disinfect various liquid disinfectants without corrosiveness of air conditioning materials; for some places where liquid disinfectants are not easy to reach, it can be added into the air to disinfect Disinfectant method.